(3) 75 HP Bingham Pumps
(3) 40 HP Bingham Pumps
(2) 100 HP Bingham Pumps
(2) 100 HP Gould Pumps
(1) 75 HP Sundyne Pump
(1) 20 HP Byron Jackson Pump
(1) 7.5 HP Sundyne Pump
(1) 7.5 HP Bingham Pump
(1) 2 HP Durco Pump
(1) 3 HP Worthing Pump
Quebec, Canada
75 HP Bingham Pump
Year of Installation | 1987 |
---|---|
Model# |
VCR |
Serial# |
2M042 |
Size |
2x3x6.5 |
Capacity GPM |
165 |
RPM |
3600 |
Total Discharge Head |
1575 |
HP |
75 |
75 HP Bingham Pump
Year of Installation | 1987 |
---|---|
Model# |
VCR |
Serial# |
2M043 |
Size |
2x3x6.5 |
Capacity GPM |
165 |
RPM |
3600 |
Total Discharge Head |
1575 |
HP |
75 |
75 HP Bingham Pump
Year of Installation | |
---|---|
Model# |
|
Serial# |
|
Size |
|
Capacity GPM |
|
RPM |
|
Total Discharge Head |
|
HP |
40 HP Bingham Pump
Year of Installation | 1987 |
---|---|
Model# |
VCR |
Serial# |
2452A |
Size |
3x4x8A |
Capacity GPM |
270 |
RPM |
3600 |
Total Discharge Head |
620 |
HP |
40 |
40 HP Bingham Pump
Year of Installation | 1987 |
---|---|
Model# |
VCR |
Serial# |
2453A |
Size |
3x4x8A |
Capacity GPM |
270 |
RPM |
3600 |
Total Discharge Head |
620 |
HP |
40 |
40 HP Bingham Pump
Year of Installation | 1987 |
---|---|
Model# |
VCR |
Serial# |
2M268 |
Size |
3x4x8A |
Capacity GPM |
270 |
RPM |
3600 |
Total Discharge Head |
620 |
HP |
40 |
100 HP Bingham Pump
Year of Installation | 1990 |
---|---|
Model# |
VCR |
Serial# |
2M376 |
Size |
2x3x6 1/2A |
Capacity GPM |
136 |
RPM |
3600 |
Total Discharge Head |
1694 |
HP |
100 |
100 HP Bingham Pump
Year of Installation | |
---|---|
Model# |
|
Serial# |
|
Size |
|
Capacity GPM |
|
RPM |
|
Total Discharge Head |
|
HP |
100 HP Gould Pump
Year of Installation | 1988 |
---|---|
Model# |
VIT-T |
Serial# |
T-310160-1 (25STG) |
Size |
4x6x8 AHC |
Capacity GPM |
160 |
RPM |
3550 |
Total Discharge Head |
3000 |
HP |
100 |
100 HP Gould Pump
Year of Installation | 1988 |
---|---|
Model# |
VIC-T |
Serial# |
T-310160-2 (25STG) |
Size |
4x6x8 AHC |
Capacity GPM |
160 |
RPM |
3550 |
Total Discharge Head |
3000 |
HP |
100 |
75 HP Sundyne Pump
Year of Installation | 1970 |
---|---|
Model# |
LMV 311 |
Serial# |
74113085 |
Size |
2x3x9.9 |
Capacity GPM |
115 |
RPM |
7000 |
Total Discharge Head |
1500 |
HP |
75 |
20 HP Byron JacksonPump
Year of Installation | 1977 |
---|---|
Model# |
VLT |
Serial# |
77TM0925 |
Size |
3x4x12 |
Capacity GPM |
150 |
RPM |
3500 |
Total Discharge Head |
520 |
HP |
20 |
7.5 HP Sundyne Pump
Year of Installation | 85 |
---|---|
Model# |
LMV |
Serial# |
85117063 |
Size |
2x3x11.9 |
Capacity GPM |
42 |
RPM |
3500 |
Total Discharge Head |
671 |
HP |
7.5 |
7.5 HP Bingham Pump
Year of Installation | 1985 |
---|---|
Model# |
CAP |
Serial# |
2132A |
Size |
3x6x11.5 |
Capacity GPM |
253 |
RPM |
1800 |
Total Discharge Head |
90 |
HP |
7.5 |
2 HP Durco Pump
Year of Installation | 1978 |
---|---|
Model# |
|
Serial# |
3X2V-13/110 |
Size |
3X2V-13/110 |
Capacity GPM |
100 |
RPM |
1200 |
Total Discharge Head |
50 |
HP |
2 |
3 HP Worthing Pump
Year of Installation | 1976 |
---|---|
Model# |
D-1132 |
Serial# |
Y643717 |
Size |
4x3x8 |
Capacity GPM |
200 |
RPM |
1800 |
Total Discharge Head |
50 |
HP |
3 |